Illinois 2025-2026 Regular Session

Illinois Senate Bill SB2193

Introduced
2/7/25  
Refer
2/7/25  
Refer
2/25/25  

Caption

SCH CD-SCHOOL VENTILATION

Summary

SB2193 would amend the Illinois School Code to create new school ventilation and indoor air quality requirements for public school districts, including Chicago. It directs the State Board of Education, working with the Department of Public Health, to develop and distribute an educational document on the value of good indoor air quality for school personnel and leadership. School districts would then be required to provide that material to instructors, staff, administrators, and district leadership in both PDF and physical form. The bill also sets out facility-related standards for active classrooms, defined as rooms used for in-person instruction. Subject to funding, districts would need to ensure that non-mechanically ventilated classrooms have operable windows, that all active classrooms have air quality monitors or sensors and in-room air cleaners, and that schools keep five years of records when recommended parts-per-million levels are exceeded. It further requires additional air cleaners and monitors for common school spaces such as health offices, libraries, and cafeterias, and calls for ventilation verification assessments of mechanical systems to confirm they are operating as designed and meeting applicable building codes.

Impact

If enacted, SB2193 would add three new sections to the School Code and impose new duties on the State Board of Education, school districts, regional offices of education, and intermediate service centers. The bill would create a statewide framework for indoor air quality education, monitoring, remediation equipment, recordkeeping, and ventilation assessments in schools. Its requirements are expressly tied to appropriations and funding, so implementation would depend on future state funding and would phase in over time, including a two-year compliance window after funding becomes available for certain window-related requirements.

Sentiment

Based on the bill text and the absence of recorded committee debate or votes, the measure appears to be framed as a public health and school safety initiative rather than a partisan or controversial policy change. The overall tone of the proposal is preventive and supportive of classroom health, with emphasis on air quality, ventilation, and student/staff well-being. Because no transcripts or vote history are provided, there is no documented formal support or opposition in the available materials.

Contention

The main potential points of contention are likely to be cost, feasibility, and implementation timing. The bill repeatedly makes obligations contingent on funding or appropriation, suggesting that districts may face significant capital and operating expenses for windows, air cleaners, sensors, and ventilation assessments. Another possible issue is administrative burden, including recordkeeping for five years and ensuring equipment is not shared between classrooms. Stakeholders most likely to raise concerns would be school districts and education administrators, while supporters would likely include public health advocates, parents, teachers, and school facility safety proponents.

Companion Bills

No companion bills found.

Similar Bills

No similar bills found.